ENERGY-ISOLATION & EEZ-ON® PRODUCTSL-O-X® Valves • EEZ-ON® ValvesL-O-X® Valves with EEZ-ON® OperationENERGY-ISOLATION & EEZ-ON® PRODUCTSL-O
10 © 2012, ROSS CONTROLS. All Rights Reserved.Series 27 Solenoid Piloted Valves with L-O-X® ControlRemote Control in a Full Range of Valve SizesPIL
www.rosscontrols.com 11Series 27 EEZ-ON® ValvesA Gradual Start-up for Pneumatic CircuitsAIR PRESSURE TO INLETWhen air pressure is first applied to th
12 © 2012, ROSS CONTROLS. All Rights Reserved.Series 27 EEZ-ON® ValvesGradual Start-up plus Pressure Controlled and Line ExhaustPILOT NOT ENERGIZED
www.rosscontrols.com 13Series 27 Manual L-O-X® Valves with EEZ-ON® OperationL-O-X® handle open and pilot not ener-gized. Pilot air is blocked by the
14 © 2012, ROSS CONTROLS. All Rights Reserved.Right-Angle EEZ-ON® ValvesEEZ-ON® Valves are used to gradually apply air pressure downstream when su
www.rosscontrols.com 15STANDARD SPECIFICATIONS: For valves on this page. Ambient/Media Temperature: Plastic or Metal bowl: 40° to 125°F (4° to 52°C
16 © 2012, ROSS CONTROLS. All Rights Reserved.DIMENSIONS inches (mm) Weight † Bowl A B * C ** Dept
www.rosscontrols.com 17Air Entry Packages with Sensing Valve and with Control Reliable Energy Isolation Model Air Entry Port Size CV Dimens
18 © 2012, ROSS CONTROLS. All Rights Reserved.AccessoriesMultiple Lock-out DeviceMuffl-Air® SilencersROSS MUFFL-AIR® silencers substantially reduce
www.rosscontrols.com 19 Extra Port Blocks An extra port block can be placed between modules to provide two auxiliary 1/4 NPTF ports. Its mounting
2 © 2012, ROSS CONTROLS. All Rights Reserved.Regulations for Workplace SafetyThe Occupational Safety and Health Administration (OSHA) regulation (2
Printed in the U.S.A. - Rev. 05/12 © 2012, ROSS CONTROLS. All Rights Reserved. Form A10075ROSS CONTROLSTroy, MI., U.S.A.Telephone: + 1-248-764-1800
www.rosscontrols.com 3CONTENTS PageRegulations & Standards ... 2-3Series 15 L-O-X® Valves with EEZ-ON
4 © 2012, ROSS CONTROLS. All Rights Reserved.Series 15 L-O-X® Valves with EEZ-ON® OperationCombines L-O-X® Shut-off with EEZ-ON® Gradual StartsVALV
www.rosscontrols.com 5Series 15 Manual L-O-X® Valves • Reliable, Low-Cost Control • 1/4 to 3/8 PortsVALVE CLOSEDWhen the red handle is pushed in
6 © 2012, ROSS CONTROLS. All Rights Reserved.Series 15 Manual L-O-X® Valves • Reliable, Low-Cost Control • 3/8 to 1¼ PortsVALVE CLOSEDWith a sh
www.rosscontrols.com 71212310BACSeries 15 Manual L-O-X® Valves• Reliable, Low-Cost Control • 1½ and 2 PortsVALVE CLOSEDWith a short push of the
8 © 2012, ROSS CONTROLS. All Rights Reserved.3 Inch L-O-X® Valve for Lockout Five good reasons to equip your pneumatic systems with our energy iso
www.rosscontrols.com 9123Y3Series 27 Manual Piloted Valves with L-O-X® ControlPort Sizes up to 2½ for Larger SystemsVALVE OPENWith the red handle pu