Ross-controls REDUNDANT 2_2 WAY WITH SENSING SERIES 27 Manuale Utente

Navigare online o scaricare Manuale Utente per Accessori per l'aria Ross-controls REDUNDANT 2_2 WAY WITH SENSING SERIES 27. Ross Controls REDUNDANT 2_2 WAY WITH SENSING SERIES 27 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 2
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Series SV27 Sensing Valves
Pilot Operated Check
Solenoid Pilot Controlled and
Pressure Controlled
Category 2 & 3 Safety Applications
Load Holding
ROSS’ new Series SV27 Sensing Valves Pilot Operated
Check, based upon the proven Series 27 valve family, combine
the tough, dirt tolerant characteristics of poppet technology with
sensing for actual internal position and state. Electrical feedback
is provided via a positively-driven, safety-rated DPST (Double-
Pole Single-Throw) switch with both normally open (NO) and
normally closed (NC) contacts. The DPST switch is actuated
whenever the valve is not in the normal home position.
An optional visual pressure indicator (988A30) or pressure
switch kit (608A86) can be installed into the 1/8 NPT pressure
verifi cation port (PV) for verifi cation of pressure release.
www.rosscontrols.com
New Product
Information
Pressure controlled and solenoid pilot controlled versions.
Poppet construction for near zero leakage & high dirt tolerance.
Directly operated safety-rated force-guided positive-break
status switch (DPST).
Holds a vertical load in the event of loss of air pressure
(and electrical power with solenoid pilot operated models).
FEATURES:
EN 954-1, ISO 13849-1,
& AS4024-1
(3/4 bodies only,
other sizes approval pending)
1/4” Signal port
1/8” PV
C
V
V
C
1/8” EPS
1/8” PV
Sensing Valves PO Check
Pressure Controlled
Sensing Valves Redundant PO Check
V
1/4” Signal port
1/8” PV
C
1/4” Signal port
1/8” PV
C
V
1/8” PV
1/8” EPS
1/8” PV
1/8” EPS
Pressure Controlled
Sensing Valve PO Check
Pressure Controlled
Sensing Valve Redundant PO Check
Pressure Controlled
GENERAL:
STANDARD SPECIFICATIONS:
Solenoid: AC or DC power. Rated for continuous duty.
Standard Voltages: 110 volts AC, 50/60 Hz; 24 volts DC.
Other voltages available.
Power Consumption:
CNOMO Style: 11 VA inrush, 8.5 VA holding on 50 or 60 Hz;
6 watts on DC.
Pacer Style: 87 VA inrush, 30 VA holding on 50 or 60 Hz;
14 watts on DC.
Ambient Temperature: 40° to 120°F (4° to 50°C).
Media Temperature: 40° to 175°F (4° to 80°C).
Flow Media: Filtered air 5 micron recomended.
Inlet Pressure: 40 to 150 psig (2.8 to 10 bar).
Pilot Pressure: Equal to or greater than inlet pressure.
Switch Current/Voltage Max.: 2.5 A/120 volts AC.
Switch Current/Voltage Min.: 50 mA/24 volts DC.
NOTE: Electrical life of switch varies with conditions and
voltage; rated in excess of 15 million cycles.
Solenoid Pilot Controlled
Solenoid Pilot Controlled
Vedere la pagina 0
1 2

Sommario

Pagina 1 - Information

Series SV27 Sensing ValvesPilot Operated CheckSolenoid Pilot Controlled and Pressure Controlled Category 2 & 3 Safety ApplicationsLoad HoldingROSS

Pagina 2

Solenoid Pilot Controlled Models (CNOMO Style) Model Numbers* Port Size Cv Dimensions inches (mm) Weight 1, 2

Commenti su questo manuale